Fujian zhichuan mechanical equipment Co., Ltd.

Fujian zhichuan mechanical equipment Co., Ltd.

Manufacturer from China
Verified Supplier
2 Years
Home / Products / Vickers Cartridge Valve /

Vickers SV13-10-0P-240AGH Cartridge Valve Solenoid 24 VDC Safety New Original

Contact Now
Fujian zhichuan mechanical equipment Co., Ltd.
Visit Website
City:xiamen
Country/Region:china
Contact Person:Mrli
Contact Now

Vickers SV13-10-0P-240AGH Cartridge Valve Solenoid 24 VDC Safety New Original

Ask Latest Price
Video Channel
Brand Name :Vickers
Model Number :SV13-10-0P-240AGH
Certification :cc
Place of Origin :America
MOQ :1
Price :RMB/100-10000/PC
Payment Terms :T/T
Supply Ability :10PCS/days
Delivery Time :3 work days
Packaging Details :wooden case/carton
Valve Size :3
Valve Coil Voltage :24 VDC
Valve Operation :Solenoid
Valve Type :Cartridge Valve
Valve Mounting Size :7/8-14 UNF
Valve Coil Type :Class H
Valve Body Material :Steel
Warranty :1 year
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Product Description:

Advantages and features of Vickers cartridge valves


‌Compact structure and efficient design‌

The cover plate or threaded cartridge structure is small in size and requires little installation space, which is especially suitable for complex equipment layout.

The modular design supports flexible assembly, and the valve group configuration can be quickly adjusted according to needs to reduce system complexity.

High-precision control performance‌

The main valve core position can be precisely adjusted through the pilot valve or proportional solenoid valve, which supports continuous control of flow, pressure and direction and reduces hydraulic shock.

Some models have built-in proportional amplifiers to simplify wiring and improve control response speed.

Versatility and compatibility‌

The valve hole specifications are unified, and different functional valves (such as overflow valves and reversing valves) can be used interchangeably, which significantly reduces the processing and maintenance costs of valve blocks.

Complies with ISO-4401 standards and is suitable for a variety of hydraulic system integration requirements.

High reliability and long life‌

The valve core is made of high-quality materials and double-seal structure, which is resistant to high pressure (up to 350bar) and high flow shock and adapts to harsh working conditions.

The low leakage design reduces energy loss and reduces the risk of oil contamination.


‌Maintenance convenience‌

The plug-in design supports quick disassembly and replacement, and maintenance can be performed without removing the pipe joints, reducing downtime.


The fully enclosed electromagnetic coil has a high protection level (IP67), prevents oil penetration and is easy to replace.


Precautions for use


Installation specifications‌

Special tools must be used for installation to ensure that the valve body and the valve hole fit tightly to avoid leakage or valve jamming due to improper assembly.


The diameter must be consistent in the superimposed valve circuit to avoid affecting system performance due to size mismatch.


Power supply and wiring requirements‌

Select the power supply wire diameter strictly according to the voltage specification (such as 24V or 12V). Long-distance power supply requires an increased wire diameter to reduce the voltage drop.


The signal line must be separately shielded and grounded in a standardized manner to prevent abnormal control caused by electromagnetic interference.


‌Oil and environmental management‌

The oil cleanliness must meet the ISO 18/15 standard, and the filter must be cleaned regularly (recommended once every 2-3 months) to prevent impurities from clogging the valve core.


Avoid long-term operation in high temperature (>80℃) or strong vibration environment, and install a shock absorber if necessary.


Maintenance and debugging‌

Pressure calibration is required after the first installation or replacement to ensure that the system pressure matches the valve setting value.


Regularly check the aging of seals (especially under high temperature conditions) and replace damaged seals in time.


‌Fault prevention‌

Abnormal power supply (voltage fluctuation, poor line contact) will cause the solenoid valve to not be attracted. It is necessary to configure a voltage stabilizer and check the line regularly.


Long-term out-of-service or spare valve groups need to be rotated regularly to prevent the seals from failing due to static adhesion.


Summary
Vickers cartridge valves have become core components of hydraulic systems with their compact design, high-precision control and versatility, especially suitable for high-demand scenarios such as construction machinery and injection molding equipment. When using, you need to pay attention to the installation specifications, oil cleanliness and power supply stability to ensure long-term reliable operation.

Valve Configuration 2-Way
Valve Coil Connection DIN 43650
Valve Flow Rating 20GPM
Valve Pressure Rating 5000 PSI
Valve Seal Material Nitrile
Valve Mounting Type Threaded
Valve Size 3
Valve Coil Voltage 24 VDC
Valve Operation Solenoid
Valve Type Cartridge Valve

Vickers SV13-10-0P-240AGH Cartridge Valve Solenoid 24 VDC Safety New Original

FAQ

Q1: Wonder if you accept small orders?
A1: Do not worry. Feel free to contact us .in order to get more orders and give our clients more convener ,we accept small order.

Q2: Can you send products to my country?
A2: Sure, we can. If you do not have your own ship forwarder, we can help you.

Q3: What's your payment terms ?
A3: By T/T,LC AT SIGHT,100% full payment.

Q4: How long is your production lead time?
A4:It depends on product and order qty. Normally, it takes us 15 days for an order with MOQ qty.

Q5: When can I get the quotation ?
A5: We usually quote you within 24 hours after we get your inquiry. If you are very urgent to get the quotation.Please call us or tell us in your mail, so that we could regard your inquiry priority.

Inquiry Cart 0